Products

Position:Home > Products > Electric control valve
  • Single seat control valve, ZAZP electric single seat regulating valve
  • Category:Electric control valve
ordering hotline:18018653319

product manual

ZAZP series electric through single seat regulating valve is composed of a DKZ type series of straight travel electric actuator and through single seat valve is composed of two parts, with the single phase AC 220V power supply for power, accept 0~10mA or 4~20mA DC signal, automatic control valve opening, continuous regulation of pipeline fluid pressure, flow, level and other parameters. The product is sensitive, convenient use, energy and signal transmission characteristics of rapid. Widely used in electric power, metallurgy, chemical industry, textile and other industrial automatic control system. 
 

Materials of main parts:

 

The valve body materialMaterial gradeNominal pressure(MPa)Applicable temperature range(℃)
At room temperatureHeat type
Cast ironHT2001.6-20~200-
Cast steelZG230~4504.0,6.4-40~250-40~450
Cast stainless steelZG1Cr18Ni9Ti ZG0Cr18Ni12Mo2Ti4.0,6.4-40~250-60~450

Main technical parameters

Nominal diameter DN(mm)G3/4″20253240506580100125150200
Seat diameter DN(mm)34567810121520263240506680100125150200
The rated flow coefficient Kv0.080.120.20.320.50.81.223.2581220325080120200280450
Flow characteristics

A straight line

Linear, equal percentage
Nominal pressure PN(MPa)101.6,4.0,6.4
Connection typePipe thread connection G3/4Flange connection: PN1.6 according to the standard of JB79-59 PN4.0 according to JB79-59 standard;
With the executive agency modelDKZ-310DKZ-310DKZ-310DKZ-410DKZ-410
A pumping thrust(N)40004000400064006400
Trip L(mm)101016254060
Total travel time (S)8812.5203250

Mode of action

Electric open (K) commonly used electric closed (B);

Input signal

0~10mA  4~20mA  DC
Power supply220V;50~60Hz
The inherent adjustable ratio R30:1

 The main technical performance indicators

ProjectTechnical performance index
The basic error %≤±5
The return difference %≤3
The dead zone %≤5
Leakage0.01%×Rated capacity
The rated flow coefficient error %≤ ± 10; when KV ≤ 6.3, ≤ ± 15

 

Structure diagram:

       

Ordering instructions
Type and name 1 product 2 nominal diameter DN (mm) 3 nominal pressure
4 flow characteristics of 5 valve material 6 rated flow coefficient of 7 medium type and temperature range of 8 valve before and after the pressure (differential pressure) and the control signal of the 9 power supply voltage
10 other special requirements

Items with * are requiredI want to consult

* Name: Please fill in your real name
* Phone: Please fill in your real mobile phone
E-mail:
Contact address:
*Ordering intention:
* Verification code:    Can't see?

Service

Service Time:00-24:00

Service

18018653319
7*24 hour customer service hotline

Wechat

Follow the official WeChat